TM 1-1520-238-23
1-24
1.14.
FUEL SERVICING GRAVITY METHOD continued
NOTE
If fuel quantity indications do not match,
refer to fuel quantity indication operation-
al check (TM 1-1520-238-T).
n. Check fuel indicators (23).
(1) Verify that quantity of fuel put in tanks
matches quantities shown on indicators (23).
(2) Set REFUEL VALVE switch (5) to CLOSE.
(3) Check that indicator (6) is not lighted.
(4) Refer to TM 1-1520-238-T if indicator (6) re-
mains lighted.
(5) Set FUEL QTY IND switch (4) to OFF.
o. Disconnect battery (1).
(1) Detach connector P87 (2) from receptacle
(BT1)J3 (3).
p. Remove static ground lines (FM 10-68).
q. Secure access doors R160 and R295 (para
2.2).
END OF TASK
CLOSE
OPEN
OFF
IND ON
4
6
5
23
M04-1846-9
M04-1846-7
1
21
3