TM 1-1520-238-23
4-582
4.169.
CPG POWER QUADRANT DISASSEMBLY/ASSEMBLY (AVIM) continued
NOTE
Power lever handle has spring tension
from the trigger release spring. To pre-
vent loss of spring, hold spring while re-
moving handle.
(1) Remove left power handle (11) from power
lever (12).
(a) Hold handle (11). Remove screw (13).
(b) Hold spring (14). Remove handle (11)
from lever (12).
(2) Remove right power handle (15) from power
lever (16).
(a) Hold handle (15). Remove screw (17).
(b) Hold spring (18). Remove handle (15)
from lever (16).
(3) Remove seal separator (19) from power
quadrant (2).
(a) Loosen two set screws (20) and remove
separator (19).
(4) Remove five screws (21) while holding lever
assembly (10) on right side of power quad-
rant (2).
(a) Remove lockwire from five screws (21).
(b) Remove five screws (21).
GO TO NEXT PAGE
M04-3927-2
17
15
11
14
13
18
16
12
2
M04-3927-3
2
20
20
19
M04-3927-4
21
2
10