UTILITY HYDRAULIC ACCUMULATOR REMOVAL/INSTALLATION continued
7.82.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open
EMERG HYD circuit breaker.
c. Remove nitrogen gas tube (1) from hydraulic
accumulator (2).
(1) Remove nut (3) from adapter (4).
d. Remove aft retaining strap (5) from accumula-
tor (2).
(1) Remove two bolts (6) and washers (7).
e. Remove reservoir return tube (8) from accu-
mulator (2).
(1) Place rags under tube (8) to catch hydraulic
fluid spills.
(2) Remove nut (9) from adapter (10).
GO TO NEXT PAGE