TM 1-1520-238-23
7-405
7.108.
UTILITY LOW LEVEL SHUTOFF VALVE REPLACEMENT continued
7.108.3. Removal
a. Detach connector P1011 (1) from receptacle
(HP6)J1 (2).
b. Remove tubes (3) and (4) from two unions (5).
(1) Hold union (5). Remove nut (6).
(2) Hold union (5). Remove nut (7).
c. Remove valve (8) from armor plate (9).
(1) Remove two screws (10) and washers (11)
from clamp (12).
(2) Remove valve (8) from armor plate (9).
d. Remove unions (5) from valve (8).
(1) Remove and discard packings (13) and valve
(8).
7.108.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
7.108.5. Inspection
a. Check removed and attaching parts for nicks,
scratches, rounded flats, and stripped or
damaged threads (para 7.56).
b. Check removed and attaching parts for corro-
sion (para 1.49).