TM 1-1520-238-23
7-477
7.124.
SDC FILTER ELEMENT REMOVAL/INSTALLATION continued
7.124.3. Removal
a. Remove temperature sensor (1) from filter
plug (2).
(1) Detach connector P1323 (3) from receptacle
(S132)J1 (4).
(2) Hold plug (2). Use crowfoot.
(3) Remove sensor (1) from plug (2).
(4) Remove and discard packing (5) from sensor
(1).
b. Remove filter element (6) from filter recess (7)
of SDC (8).
(1) Remove plug (2). Use crowfoot.
(2) Remove and discard packing (9) from plug
(2).
(3) Remove filter (6) from recess (7).
(4) Remove and discard two packings (10) from
filter (6).
7.124.4. Cleaning
a. Clean filter (para 1.47).
b. Wipe removed and attaching parts with a
clean rag.
7.124.5. Inspection
a. Check filter for cracks and dents. None al-
lowed.
b. Check SDC, temperature sensor, and attach-
ing parts for cracks, dents, and scratches
(para 7.114).
c. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
3
4
1
5
8
M04-2157-2
2
6
7
10
9
10