TM 1-1520-238-23
9-222
9.60.
START MODE RELAY PANEL REMOVAL/INSTALLATION continued
d. Check mounting area for loose, damaged, or
missing nutplates (para 9.1).
e. Check attaching hardware for stripped or
damaged threads (TM 1-1500-204-23).
f. Check removed and attaching parts for corro-
sion (para 1.49).
9.60.6. Installation
a. Install panel (2) on box (9).
(1) Position panel (2) on box (9).
(2) Install four screws (10) and washers (11).
b. Attach connectors P977 (6) and P978 (5) to
panel (2).
(1) Attach connector P977 (6) to receptacle
(A330)J1 (8). Use socket head key set.
(2) Attach connector P978 (5) to receptacle
(A330)J2 (7). Use socket head key set.
c. Attach wire (1) to relay panel (2).
(1) Install screw (3) through washer (4) and wire
(1) into panel (2).
d. Inspect (QA).
e. Perform power plant maintenance operational
check
(engine
1
or
engine
2)
(TM 1-1520-238-T).
f. Install access panel L200 (para 2.2).
END OF TASK
9
2
11
10
1
M04-3309-4
4
3
M04-3309-5
6
2
5
8
7