TM 1-1520-238-23
9-518
9.136.
MASS TERMINATION CONNECTOR (MTC) WITH SHIELD BUS (1 OR 2 INCH) REPAIR continued
d. When working on harness installed in aircraft,
attach static ground bus (11) to wafer (6). Very
gentle insertion is sufficient for static grounding.
NOTE
Wafers are identified as A or B to corre-
spond to A or B side of connector. Con-
tacts are 1 thru 10 (1.0 INCH) or 1 thru 20
(2.0 INCH).
e. Identify wire (12) to be removed from wafer (6).
f. Make a shallow cut along length of wafer
sleeve (13) and bus sleeve (14) marked for
removal. Do not cut through sleeves (13) and
(14).
g. Install bus module (15) in repair fixture (16).
h. Install wafer (6) in repair fixture (16).
(1) Install wafer (6) with wafer key (17) face down
under clamping cover (18).
(2) Bus (7) fits on alinement pins (19).
i. Attach ground lead (20) to a reliable ground.
GO TO NEXT PAGE
M04-3066-31
11
6
6
11
17
15
19
18
16
14
7
12
13
6
20
M04-3066-32