TM 1-1520-238-23
10-143
10.28.
FORWARD FUEL CELL REMOVAL continued
WARNING
High pressure air exists. Air pressure
from the pneumatic vacuum cleaner
shall be vented and the regulator gage
indicates 0 psi before disconnecting
regulator. Failure to do so could cause
death or serious injury. Observe all
safety precautions.
(10) Turn knob (72) counterclockwise until 0 psi is
indicated on gage (73).
(11) Remove filler (71) from plug (64).
x. Remove plate (54) and handle (55) from pad
(56).
(1) Unfasten 12 captive screws (57).
(2) Remove eight bolts (58) and washers (59).
(3) Remove four bolts (60) and washers (61).
(4) Remove and discard packing (74).