10.135. FUEL QUANTITY INDICATOR TEST (TF 579) SET INSTALLATION/REMOVAL continued
c. On pilot center circuit breaker panel, ensure
CAUT, UTIL SEC, and ENG INST circuit break-
ers are closed.
d. Enter CPG station (para 1.56). Observe all
safety precautions.
e. On CPG left console circuit breaker panel No.
1, ensure CAUT, UTIL SEC, and ENG INST cir-
cuit breakers are closed on CPG left console
circuit breaker panel No. 1.
f. In aft avionics bay (R295), ensure MAINT LT
circuit breaker is closed.
g. In right transmission bay (R190), ensure AC
and DC ELEC UTIL PWR circuit breakers are
closed.
GO TO NEXT PAGE
M04-3075-3
CIRCUIT BREAKER
PANEL NO. 1
CPG STATION
M04-3075-4
R295
MAINT LT
CIRCUIT
BREAKER
AC AND DC
CIRCUIT
BREAKERS
M04-3075-5