TM 1-1520-238-23
Change 2
11-173
11.33.
CPG COLLECTIVE STICK BUCS SELECT TRIGGER GRIP SWITCH REPLACEMENT continued
d. Check removed and attaching parts for corro-
sion (para 1.49).
11.33.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install switch (4) on grip (2).
(1) Apply a small bead of adhesive around the
circumference of switch mounting shoulder
(10). Use adhesive (item 8, App F).
(2) Press switch (4) in mounting hole of grip (2).
(3) Wipe away excessive adhesive.
(4) Install trigger (9), trigger guard (8), and spring
(7) on grip (2).
(5) Install control grip pin (6).
(6) Secure grip control pin (6) at both ends with a
small drop of adhesive. Use adhesive (item 8,
App F).
(7) Solder identified wires (5) to switch (4). Use
soldering iron and solder (item 189, App F)
(TM 55-1500-323-24).
GO TO NEXT PAGE
2
5
9
8
7
6
M04-3450-6A
10
4