12.62.
ICE DETECTOR SIGNAL PROCESSOR PROBE OSCILLATOR REFERENCE OR RATE OUTPUT
CCA REPLACEMENT (AVIM)
12.62.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
12.62.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
Equipment Conditions:
Ref
Condition
12.60
Ice detector signal processor CCA stack re-
moved
NOTE
This task is typical for replacement of
probe oscillator reference or rate output
CCA.
GO TO NEXT PAGE
M04-3764-1
PROBE REFERENCE
OSCILLATOR CCA
RATE OUTPUT CCA