TM 1-1520-238-23
12-284
12.64.
ICE DETECTOR SIGNAL PROCESSOR EMI FILTER REPLACEMENT (AVIM) - continued
12.64.6. Installation
a. Install new EMI filter (2) on mounting bracket
(3).
(1) Hold EMI filter (2).
(2) Install lockwasher (5) and nut (4).
WARNING
Soldering gun can cause severe burns
to personnel and start fires. Observe
all safety precautions when using
soldering gun. If injury occurs, seek
medical aid.
b. Solder identified wires (1) to EMI filter (2). Use
soldering gun and solder (item 189, App F)
(TM 55-1500-323-24).
c. Inspect (QA).
d. Install ice detector signal processor CCA
stack (para 12.60).
END OF TASK
M04-3766-3
1
2
3
4
5