TM 1-1520-238-23
12-313
12.74.
WINDSHIELD ANTI-ICE TEMPERATURE CONTROL BOX TERMINAL STUD REPLACEMENT
(AVIM) - continued
12.74.3. Removal
WARNING
Soldering gun can cause severe burns
to personnel and start fires. Observe
all safety precautions when using
soldering gun. If injury occurs, seek
medical aid.
a. Identify and desolder wires (1) from terminal
stud
(2).
Use
soldering
gun
(TM 55-1500-323-24).
b. Remove and discard terminal stud (2) from
mounting base stud (3).
12.74.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
12.74.5. Inspection
a. Check removed and attaching parts for dam-
age (para 12.46).
GO TO NEXT PAGE
M04-3784-2
3
2
1