TM 1-1520-238-23
15-14
15.3.
APU INSTALLATION - continued
9
5
4
8
12
7
14
13
12
3
2
1
11
10
M04-1574-2
VIEW ROTATED
VIEW ROTATED
6
WARNING
Inspect lifting lug for damage, bends, or cracks. Insure lifting hook or clevis is of proper size to
prevent side loads from being imposed on lifting lug. Failure of lifting lug can cause structural
damage or injury personnel. If injury occurs, seek medical aid.
a. Insert lifting hook (1) into APU lifting lug (2).
b. Lift APU (3) with crane until weight is off mounts (4), (5), and (6).
c. Remove APU (3) from APU workstand (7).
(1) Remove workstand knobs (8) and (9) from mounts (4) and (5).
(2) Remove pin (10) from support (11) and mount (6).
(3) Attach tag lines (12) to combustor cap (13) and PTO clutch (14).