PYLON WIRE HARNESS REPLACEMENT - continued
g. Remove clamp (27) from harness (19).
(1) Remove screw (28), washer (29), clamp (27),
and spacer (30) from bracket (31).
(2) Remove clamp (27) from harness (19).
h. Remove two clamps (32) from harness (19).
(1) Remove nut (33), washer (35) from clamp
(32) securing P508 harness.
(2) Hold nut (33). Remove screw (34) and wash-
er (35).
(3) Remove clamp (32) from harness (19).
i. Detach connector P507 (36) from receptacle
J507 (37) on pylon actuator (38).