TM 11520238T1
472
Change 5
410 PYLN SYSTEM INTERACTIVE FD/LS
410
CHECK (cont)
TASK
RESULT
e. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
If this FD/LS check is to be followed by ESC
SYSTEM OPERATIONAL CHECK
(TM 9-1090-208-23-2), omit step 3.
3. Perform SYSTEMS POWER DOWN (para 32).
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
EXT STORES
CONTROL BOX
NOGO AFT OF LH
FAB
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2). If
troubleshooting does not
remove NOGO, replace
external stores controller
(TM 9-1090-208-23-1). If
replacement does not
remove NOGO, refer to
TM 9-1090-208-23-2.
(All) PYLN ACTUATOR
CONTROLLER
NOGO
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2).
PYLN ACTUATOR
CONTROLLER
NOGO LT INBD/LT
OUTBD
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2).
PYLN ACTUATOR
CONTROLLER
NOGO RT INBD/RT
OUTBD
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2).