TM 1-1520-238-T-4
6100
Change 5
638.
CPG LOW RPM ROTOR INDICATOR DOES NOT LIGHT WITH ELECTRICAL POWER
638
APPLIED AND ALL POWER PLANTS OFF
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between P31X and P4918.
Does open exist?
YES
Repair open wire between:
P4918 and P435A9,
P482A13 and P31X.
(A326)J7A9 and
(A326)TB110D,
(A326)TB110F and
(A326)J18A13.
Go to paragraph 612.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot the pilot
caution/warning system.
END OF TASK