TM 1-1520-238-T-6
9149
911.
AC ELECTRICAL POWER GENERATION POWER DOWN
911
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-8
Equipment Conditions:
Ref
Condition
Paragraph 910
AC ELECTRICAL POWER
GENERATION POWER
UP completed
NOTE
Refer to pilot station (fig. 997) for configuration and component locations.
1. On pilot ELEC PWR panel (fig. 999), set GEN 1 and GEN 2 switches to OFF.
2. Perform AUXILIARY POWER UNIT POWER DOWN (TM 1-1520-238-T-8).
3. Perform EXTERNAL POWER POWER DOWN (para 946).
END OF TASK