TM 1-1520-238-T-6
9626
9326. CIRCUIT BREAKER EDGE-LIGHT PANELS MAINTENANCE OPERATIONAL
9326
CHECK
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
Paragraph 945
EXTERNAL POWER
POWER UP completed
WARNING
Turn off power before detaching or attaching wires and connectors. High
current 28 VDC or 115 VAC is present. Failure to do so could result in death
or serious injury.
NOTE
Refer to pilot station (fig. 9201) and CPG station (fig. 9202) for cockpit
configuration and equipment.
M69-278
1.
PILOT EXT LT / INTR
LT PANEL
2.
PILOT ELEC PWR PANEL
3.
PILOT AFT CIRCUIT BREAKER PANEL
4.
PILOT CENTER CIRCUIT BREAKER PANEL
3
4
1
2
Figure 9201.
Pilot Station
M69-279
1.
CPG CIRCUIT BREAKER PANEL 1
2.
CPG INTR LT PANEL
1
2
Figure 9202.
CPG Station