TM 1-1520-238-T-7
10183
1061. FUEL XFEED CIRCUIT BREAKER DOES NOT STAY CLOSED WITH ORIDE
1061
SWITCH SET TO CPG
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P1 from (A402)J1. On pilot center circuit
breaker panel, open FUEL XFEED circuit
breaker. Check for short between P132 and
ground.
Does short exist?
YES
Repair shorted wire between
P132 and FUEL XFEED circuit
breaker.
Go to paragraph 1047.
NO
Go to step 2.
2. Check for short between (A402)J132 and
P191A1.
Does short exist?
YES
Repair shorted wire. Go to
paragraph 1047.
NO
Check FUEL XFEED circuit
breaker (para 1022).
Go to paragraph 1047.
END OF TASK