Table 7-16.
Malfunction Details - Continued
Indications presented
Required
Ref
Aircraft indications
Corrective
to instructor/operator
malfunction
and related effects
number
action
and trainee
MUX R
23028
CPG main CB panel.
Noncorrectable
Instructor: MUX R PYL INBD
PYL INBD
appears on CRT.
Trainee: Circuit breaker
pops. Loss of MUX communi-
cation with right inboard
pylon. Cannot fire from
right inboard pylon.
MUX
23029
CPG main CB panel.
Noncorrectable
Instructor: MUX FAB L
FAB L
appears on CRT.
Trainee: Circuit breaker
pops. Loss of MUX communi-
cations left.
MUX
23030
CPG main CB panel.
Noncorrectable
Instructor: MUX FAB R
FAB R
appears on CRT.
Trainee: Circuit breaker
pops. Loss of MUX communi-
cations right.
MUX CPG
23031
CPG main CB panel.
Noncorrectable
Instructor:
MUX CPG appears
on CRT.
Trainee: Circuit breaker
pops. Loss of MUX communica-
tions in CPG station.