TB 1-2840-248-20-20
7.
Parts to be Inspected.
NATIONAL STOCK NUMBER
NOMENCLATURE
PART NUMBER
Power Cable Assembly/
6044T60P01
(Yellow Harness)
6044T60P03
6044T6P01 SERIAL/PHASE NUMBERS
6044T60P03 SERIAL/PHASE NUMBERS
CJWU 0001 through CJWU 1999 (Phase 0)
All serial numbers are Phase III - Provided for in-
CJWU 2000 through CJWU 2472 (Phase I)
formation only.
CJWU 2500 through CJWU 2832 (Phase II)
CJWU 2900 through CJWU 3370, CJWY 0001
through CJWY 0067, GJA PG340 through GJA
PG349, GJA PK799 through GJA PK800, and
GJA PB001 through GJA PB499 (Phase III -
Provided for information purposes only).
NOMENCLATURE
NATIONAL STOCK NUMBER
PART NUMBER
Power Cable Assembly/
6044T83P02
(Blue Harness)
6044T83P05
6044T83P02 SERIAL/PHASE NUMBERS
6044T83P05 SERIAL/PHASE NUMBERS
CJWP 0001 through CJWP 3199 (Phase 0)
All serial numbers are Phase III - Provided for In-
CJWP 3200 through CJWP 3399 (Phase I)
formation only.
CJWP 3400 through CJWP 9999 (Phase I)
CJWJ 0001 through CJWJ 9999, GJA PG390
through GJA PG399. and GJA PH303 through
GJA PH399 (Phase III- Provided for information
purposes only).
8.
Inspection Procedures.
a. Utilizing inspection mirror and flashlight, inspect the yellow and blue engine harnesses for phase 0,
I, II, or III serial numbers listed in para 7. Serial numbers are located on the rubber boots on the W4P1 and
W5P1 cable connectors. If a yellow or blue engine harness is identified as a phase 0, I, or II harness serial
number continue with the inspection. If a yellow or blue engine harness is identified as a phase III harness,
the inspection is complete for that harness. For phase 0, I, and II harnesses in stores, locate and provide the
phase 0, I, or II harness for testing. If the part number/serial number is illegible, the harness is assumed to
be phase 0, I, or II.
b. Remove the phase 0, I, or II yellow or blue engine harness from the engine in accordance with TM
55-2840-248-23. Chapter 7 and mark appropriately in order to identify upon reinstallation. Record harness
serial numbers for phase Identification, refer to paragraph 7, and reporting purposes.
NOTE
Prior to harness testing, ensure megger is operating correctly by performing the zero and infinity
operational check provided with the test equipment. If megger fails the operational test, have meg-
ger calibrated before beginning this inspection.
c. Using AVIM/megger test box, P/N LEX 5621-10 and megger, P/N 212159, inspect each phase 0, I,
and II harness in accordance with reference 13a for electrical insulation resistance.
d. Repeat the test for phase 0, I, and II harnesses at every 250 hour phase inspection until replaced by
phase III harnesses. Phase III harnesses do not require periodic inspections.
3