TM 1-1520-238-23
2-467
2.133.
NO. 1 ENGINE NACELLE REMOVAL/INSTALLATION continued
2.133.3. Removal
a. Remove wire harness W211 (1) from firewall
(2).
(1) Remove two screws (3), washers (4), and
spacer (5).
(2) Reposition wire harness (1) and clamps (6)
away from firewall (2).
WARNING
Each actuator stud must be wired to a
ground stud to prevent accidental dis-
charge.
NOTE
Fire extinguisher bracket and bottles can
be removed as one unit.
b. Enter pilot station (para 1.56). Observe all
safety precautions.
c. On pilot circuit breaker panel, open FIRE
EXTGH PLT, FIRE EXTGH CPG, and FIRE
EXTGH APU circuit breakers.
d. Install shorting wires on cartridges (para
12.38). Use wire (item 226, App F).
e. Detach primary and reserve connectors P1
(para 12.38).
GO TO NEXT PAGE
M04-4109-1
M04-4109-2
5
6
1
4
3
2
6
1
4
3
2
M04-4109-3