TM 1-1520-238-23
4-317
4.96.
LEFT NACELLE RADIATION SHIELDS REPLACEMENT continued
4.96.4. Installation
a. Install new shield (8) in nacelle (2).
(1) Position shield (8) and lanyard (13) in nacelle
(2).
(2) Install screw (12) through lanyard (13) shield
(8), and nacelle (2).
(3) Install nut (11) on screw (12).
(4) Install two screws (10) through shield (8) and
nacelle (2).
(5) Install two nuts (9) on screws (10).
b. Install new shield (6) in nacelle (2).
(1) Position shield (6) in nacelle (2).
(2) Install eight rivets (7) through shield (6) and
nacelle (2) (TM 1-1500-204-23).
c. Install new shield (4) in nacelle (2).
(1) Position shield (4) in nacelle (2).
(2) Install five rivets (5) through shield (4) and
nacelle (2) (TM 1-1500-204-23).
GO TO NEXT PAGE
8
M04-3920-5
11
12
9
10
13
5
2
4
7
M04-3920-6
6