TM 1-1520-238-23
7-23
7.5.
PRIMARY HYDRAULIC PUMP PRESSURE HOSE REPLACEMENT continued
b. Install hose (1) on check valve (6).
(1) Lubricate valve threads (6). Use clean
hydraulic fluid (item 92, App F).
(2) Hold check valve (6). Install nut (7).
CAUTION
Ensure that metal ID band is not under
clamp when installing hose. Failure to do
so could cause chafing condition on
hose.
c. Install hose (1) on bracket (2).
(1) Install clamp (5) on hose (1).
(2) Aline clamp (5) with bracket (2).
(3) Install screw (3) and washer (4) through
clamp (5) on bracket (2).
d. Inspect (QA).
e. Bleed primary hydraulic system (para 1.35).
f. Service primary hydraulic system (para 1.34).
g. Perform hydraulic system leak check (para
7.2).
h. Install access panel L200 (para 2.2).
END OF TASK
4
3
5
M04-733-3
1
2
6
7