TM 1-1520-238-23
7-258
7.62.
UTILITY HYDRAULIC PUMP SEAL DRAIN HOSE REPLACEMENT continued
7.62.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
7.62.5. Inspection
a. Check nipple and tee fitting for nicks,
scratches, chafing, and stripped or damaged
threads (para 7.56).
b. Check removed and attaching parts for corro-
sion (para 1.49).
7.62.6. Installation
a. Install new hose (1) on nuts (3) and (5).
(1) Install clamps (6) and (7).
b. Install hose (1) on nipple (2).
(1) Lubricate threads on nipple (2). Use hydraulic
fluid (item 92, App F).
(2) Hold nipple (2). Install nut (3).
c. Install hose (1) on tee (4).
(1) Lubricate threads on tee (4). Use clean
hydraulic fluid (item 92, App F).
(2) Install nut (5) on tee (4).
d. Inspect (QA).
e. Install access panel R200 (para 2.2).
END OF TASK
5
1
4
2
M04-835-2
7
3
6