TM 1-1520-238-23
8-48
8.18.
SIGNAL DATA CONVERTER REMOVAL/INSTALLATION
8.18.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
8.18.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access cover L40 removed
8.18.3. Removal
a. Remove signal data converter (1) from mount-
ing tray (2).
(1) Detach connector P401 (3) from receptacle
(A82)J2 (4).
(2) Detach connector P400 (5) from receptacle
(A82)J1 (6).
(3) Remove two screws (7).
(4) Lift converter (1) up and out of tray (2).
GO TO NEXT PAGE
M04-153-3
7
M04-153-4
6
4
1
5
2
3