TM 1-1520-238-23
9-215
9.59.
AFT AVIONICS BAY ISOLATION TRANSFORMER FILTER BOX DISASSEMBLY/ASSEMBLY
(AVIM) continued
9.59.6. Assembly
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install transformers (A342)T1 (33) and
(A342)T2 (34) in box (2).
(1) Install two screws (35) through washers (36)
and transformer (34) in box (2).
(2) Install two screws (35) through washers (36)
and transformer (33) in box (2).
(3) Solder identified wires on (A342)T1 trans-
former (33). Use soldering iron and solder
(item 189, App F) (TM 55-1500-323-24).
b. Install receptacle (A342)J3 (32) on box (2).
(1) Install four screws (28) through box (2), re-
ceptacle (32), and washers (29).
(2) Hold screws (28). Install nuts (30).
c. Install receptacle (A342)J2 (31) on box (2).
(1) Install four screws (28) through box (2), re-
ceptacle (31), and washers (29).
(2) Hold screws (28). Install nuts (30).