TM 1-1520-238-23
9-266 Change 3
9.75.
MULTICHANNEL DIMMING CONTROLLER MODULE REMOVAL/INSTALLATION
(AVIM)
9.75.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.75.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
#2 phillips screwdriver bit (item 33, App H)
1/4-inch drive screwdriver bit holder (item 175, App H)
0 - 10 inch-pound 1/4-inch drive dial indicator torque
wrench (item 444A, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1500-204-23
TM 11-6625-3085-30
CAUTION
To prevent electrostatic damage to controller module, ensure that controller modules are removed only on a
staticfree work station.
NOTE
Except for the advisory module, controller modules are identified by their operating channels. The
first number designates the pilot channel. The alphanumeric identifier immediately following the
pilots channel designates the CPG channel.
This task is applicable to controller modules 1,1A; 2,2A; 3,3A; 4,4A and controller advisory module.
GO TO NEXT PAGE