TM 1-1520-238-23
9-394
9.110.
PILOT CAUTION/WARNING PANEL HOUSING DISASSEMBLY/ASSEMBLY (AVIM) continued
NOTE
Do not desolder wires from terminal posts
unless replacing terminal posts.
(4) Remove two terminal posts (13) and wire (14)
from panel (6).
(a) Hold posts (13). Remove two screws (15)
from panel (6) and posts (13).
(b) Remove posts (13) and wire (14).
(5) Remove two clamps (16) from panel (6).
(a) Hold screws (17). Remove two nuts (18),
lockwashers (19) and washers (20).
(b) Remove two screws (17) from panel (6)
and clamps (16).
(c) Remove clamps (16).
NOTE
Do not desolder wires from hour meter
unless replacing hour meter.
(6) Remove hour meter (21) from panel (6).
(a) Hold screws (22). Remove two nuts (23)
and washers (24).
(b) Remove two screws (22) from panel (6)
and meter (21).
(c) Remove meter (21).
GO TO NEXT PAGE
M04-4217-6
15
13
6
14
M04-4217-7
17
16
6
20
19
18
M04-4217-8
22
21
6
24
23