TM 1-1520-238-23
10-238
10.48.
AFT FUEL CELL FUEL VALVE ISOLATION SWITCH REMOVAL/INSTALLATION continued
10.48.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
10.48.5. Inspection
a. Check removed and attaching parts for dam-
age (para 10.1).
b. Check electrical connector for cracks and cor-
rosion (para 10.1).
10.48.6. Installation
a. Install switch (8) on frame (9).
(1) Install two screws (10) and washers (11).
b. Attach connector P1067 (6) to receptacle
(S64)J1 (7).
c. Inspect (QA).
d. Perform pressure refueling/defueling mainte-
nance operational check (TM 1-1520-238-T).
GO TO NEXT PAGE
8
7
6
11
9
M04-930-4
10