TM 1-1520-238-23
12-25
12.7.
PILOT WINDSHIELD WIPER MOTOR REPLACEMENT - continued
NOTE
To ensure proper installation of flex shaft,
coupling must be installed between flex
shaft and motor fitting.
e. Install flex shaft (1) on motor (2). Torque nut (3)
to 100 INCH-POUNDS.
(1) Remove protective cap (5) from nut (3).
(2) Install coupling (4) and nut (3) on motor (2).
(3) Torque nut (3) to 100 INCH-POUNDS. Use
torque wrench.
(4) Lockwire nut (3) to motor (2). Use wire
(item 229, App F).
f. Inspect (QA).
g. Verify pilot windshield wiper alinement (para
12.8).
h. Perform windshield wipers maintenance op-
erational check (TM 1-1520-238-T).
i. Install signal data converter tray (para 8.21).
j. Install access cover L40 (para 2.2).
END OF TASK
M04-968-8
2
1
3
4
3
5