TM 1-1520-238-23
12-307
12.72.
WINDSHIELD ANTI-ICE TEMPERATURE CONTROL BOX CURRENT TRANSFORMER
REPLACEMENT (AVIM) - continued
12.72.3. Removal
a. Remove current transformer (1) from access
cover (2).
(1) Remove nut (3), washer (4), plastic washer
(5), slotted washer (6), washer (7), and screw
(8).
NOTE
Transformer and slotted washer will still
be attached to the wire running through
the center of them.
(2) Identify and depin one end of wire (9) from
receptacle
(A48)J2
(10)
(TM 55-1500-323-24).
(3) Remove transformer (1) and slotted washer
(11) from wire (9).
WARNING
Soldering gun can cause severe burns
to personnel and start fires. Observe
all safety precautions when using
soldering gun. If injury occurs, seek
medical aid.
b. Identify and desolder transformer wires (12)
from CCA A2 terminals (13). Use soldering gun
(TM 55-1500-323-24).
c. Remove and discard transformer (1).
GO TO NEXT PAGE
M04-3782-2
1
11
54
3
8
7
2
6
9
10
M04-3782-3
12
1
13