TM 1-1520-238-23
13-15
13.4.
ENCU AIR COOLING DUCT ASSEMBLY REMOVAL/INSTALLATION - continued
13.4.6. Installation
a. Install duct (1) on ENCU (2).
(1) Aline duct (1) on ENCU (2).
(2) Install nine screws (3) and washers (4) on
duct (1).
(3) Install three screws (3) and washers (4)
through clamps (5) and duct (1).
b. Apply adhesive at mating areas of duct (1) and
ENCU (2) and apply adhesive to completely fill
gap at each end of duct (1). Use adhesive
(item 16, App F).
c. Allow adhesive to dry 24 HOURS at 65 F mini-
mum.
d. Inspect (QA).
e. Install ENCU cooling turbine assembly (para
13.9).
END OF TASK
1
2
3
4
M04-3888-3
5