TM 1-1520-238-23
13-144
13.45.
DEFOG SYSTEM AIR MIXER AND HOSE REMOVAL/INSTALLATION - continued
d. Remove hose (19) from tube (20).
(1) Loosen clamp (21).
(2) Remove hose (19) and clamp (21).
e. Remove hose (22) from tee fitting (23).
(1) Loosen clamp (24).
(2) Remove hose (22) and clamp (24).
f. Enter pilot or CPG station (para 1.56). Observe
all safety precautions.
g. Remove hose (25) from air mixer (26).
(1) Loosen clamp (27).
(2) Remove hose (25) from nipple (28).
h. Remove mixer (26) from bracket (29).
(1) Remove two screws (30) and washers (31).
(2) Remove mixer (26).
13.45.4. Cleaning
a. Clean removed and attaching parts with a
clean rag.
13.45.5. Inspection
a. Check air mixers and tees for cracks (para
13.43).
b. Check hoses for cracks, cuts, chafing, and
deterioration (para 13.43).
c. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
19
20
21
M04-4923-5
23
24
22
M04-4923-6
3130
26
29
27
28
25