TM 1-1520-238-23
Change 8
16-101
16.22.
PYLON FRAME REMOVAL/INSTALLATION - continued
16.22.6. Repair
a. Damaged inserts (2), rivetless nutplates (3),
riveted nutplates (7), and receptacles (4) shall
be replaced (TM 1-1500-204-23).
b. Pylon frame mounting bushings (6) with an ID
greater than 1.438 INCHES are not acceptable.
c. Repair frame (1) by removing corrosion (para
1.49).
16.22.7. Installation
a. Install pylon wire harness (para 16.18).
b. Install MRTU bracket (para 16.16).
c. Install pylon controller and controller bracket
(para 16.15).
d. Install aerial bracket assembly (para 16.14).
e. Install pylon rack (para 16.4).
f. Inspect (QA).
END OF TASK
5
4
M04-2848-2A
2
6
2
3
1
3
7