FOD REMINDER
Check work area for tools and parts after completion of maintenance and inspection
TM 1-1520-238-PMS
C 3
29
Seq.
No.
Location
Item and Procedure
3.8
8
Open Electronic Equipment Access Door R295
Interior panels for cracks and cleanliness
Loose or missing hardware
Interior components for physical damage and mounting security
Electrical connectors for security
Visible wiring for chafing or damaged insulation and connection security
9
Cooling fan obstructed
10
Battery for physical damage, leakage, cleanliness, vent obstructions, and security
Battery quick disconnect for evidence of corrosion or pitting and excessive free-play
Battery connector helixes for firm fit (TM 11520238235, page 99, paragraph 9.1.3 Inspection)
Evidence of arcing or burn marks
11
Battery charger for physical damage and security
12
Battery relay terminals for evidence of corrosion, security, and loose hardware.
13
STATIC DRAIN EXTERNAL FITTING FOR OBSTRUCTION AND DAMAGE
Drain and check for moisture
3.9
14
AFT FUEL DRAIN
EXTERNAL HOSE FOR OBSTRUCTIONS
FUEL LEAKAGE
TAKE FUEL SAMPLE AND CHECK FOR WATER AND CONTAMINATION USE SAMPLE JAR
3.10
15
NITROGEN INERT MONITOR (POWER ON check perform at end of POWER OFF check)