FOD REMINDER
Check work area for tools and parts after completion of maintenance and inspection
TM 1-1520-238-PMS
C 5
76
Seq.
No.
Item and Procedure
Location
10.3
9
PYLONS (EXTERNAL STORES)
NOTE
Use 10-power magnifying lens to check yoke and rack in pivot pin area.
CRACKS, DISTORTION, CORROSION, AND MOUNTING SECURITY
Visible wiring for chafing or damaged insulation and connection security
Hydraulic lines for leakage, chafing, and connector security
SAFETY PINS AND STREAMERS INSTALLED
IF STORES NOT MOUNTED, CHECK UMBILICAL STOWAGE INSIDE PYLON LEADING EDGE FAIRING
CAUTION
When handling sensor unit, do not press on sensor window. The glass is fragile and may be scratched,
cracked, or broken.
10.4
10
Laser Detecting Sensor (forward) Left Side
Physical damage and mounting security
Clean oil, dust, or other deposits from sensor window (TM 11-5841-304-12)
10.5
11
FORWARD FUEL VENT AND LIGHTNING ARRESTOR
OBSTRUCTIONS AND CLEANLINESS
LIGHTNING ARRESTOR PACKING FOR DAMAGE AND SECURITY