“FOD REMINDER”Check work area for tools and parts after completion of maintenance and inspectionTM 1-1520-238-PMSC 783Seq.No.LocationItem and Procedure10.9–––ENGINE (work platform door LN1 opened)29Interior panels and structure for cracks, distortion, and cleanlinessLoose or missing hardwareEngine components for physical damage and mounting securityPower turbine, combustion chamber, compressor housing, exhaust nozzles, and IR suppressors for cracks, dents,and burned or buckled areasFUEL AND LUBE OIL LINES FOR LEAKAGE AND CHAFINGVisible flex cables for kinking, proper routing, and clamping security30ENGINE MOUNTS, PINS, AND BUSHINGS FOR CRACKS AND SECURITY31Deleted32Deleted33Deleted34Engine lube oil filler cap for leakage and full closure35Starter lube oil filler for proper oil level (to lip of filler neck), and for leakage and full cap closure36Overspeed and drain valve for leakage and connection security37Hydromechanical control unit (HMU) for leakage and connection security38Boost pump for leakage and connection security39FIRE DETECTION SENSORS FOR DAMAGED LENS AND MOUNTING SECURITYClean lenses with tissueVisible wiring for chafing or damaged insulation and connection security40Engine turbine case for loose or broken third stage nozzle boltsPerform engine THIR inspection (TM 55-2840-248-23)41Engine cooling louvers for missing, flaked, or chipped paint