FOD REMINDER
Check work area for tools and parts after completion of maintenance and inspection
TM 1-1520-238-PMS
91
Seq.
No.
Location
Item and Procedure
NOSE SECTION
POWER OFF
12.1
Exterior Surfaces
Skin areas for cracks and distortion
Loose or missing hardware
Access panels and fairings for mounting security
WARNING
Do not touch TADS/PNVS shroud windows. Electrical shock can result, and heaters in these fair-
ings can cause serious burns. If shock or burns occur, seek medical aid.
CAUTION
TADS/PNVS turret components can be seriously damaged if improperly handled. Do not attempt to
clean these items during the 10 hour/14 day inspection. Even if electrical power is off, touching shroud
window creates an unnecessary cleaning task.
12.2
1
TADS/PNVS Turret and Components
Upper (PNVS) and lower (TADS) turret housings for physical damage, cleanliness, and alinement
Painted surfaces for chipping or peeling that will cause reflection
PNVS mounting screws for broken torque stripe
12.3
2
Area Weapon Elevation Control Servoactuator
Cracks, distortion, corrosion, and security
Fluid leakage on servoactuator exterior
Clean exposed piston rod with hydraulic fluid (MIL-H-83282)