410 PYLN SYSTEM INTERACTIVE FD/LS
410
CHECK (cont)
TASK
RESULT
d. On DEK, press and
release ABC/1 and
()/0 keys (ADC).
If PYLON ARTICULATION
GO appears on the HOD, go
to next step.
On CDU, press and
release 1 and 0 keys
(ADD).
If PYLON BORESIGHT
NOGO RAM CHECKSUM
appears on the HOD, refer to
TM 9-1230-476-20-1 for
boresight editing and insert
correctors from the aircraft
logbook. If FCC battery is
suspect, refer to
TM 9-1230-476-20-2 (ACY).
If any other NOGO appears
on HOD, refer to
TM 9-1090-208-23-2.
If one or more FD/LS
NOGO displays listed
appear on the HOD, perform
the following in sequence:
(1) Perform SYSTEMS
POWER DOWN
(para 32).
(2) Perform CORRECTIVE
ACTION indicated for first
NOGO displayed on
HOD.
(3) Perform SYSTEMS
POWERUP
(para 31).
(4) On DEK, rotate DATA
ENTRY switch to STBY
for 5 seconds, then back
to FD/LS (ADC).
(5) Repeat FD/LS check
beginning with step b. If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 9-1090-208-23-2.
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY(ADC).