TM 11520238T1
Change 5
477
411 RKT INTERACTIVE FD/LS CHECK (cont)
411
TASK
RESULT
(4) Repeat FD/LS check
beginning with step 2. If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 9-1090-208-23-2.
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
f. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
If this FD/LS check is to be followed by
ARCS OPERATIONAL CHECK
(TM 9-1090-208-23-2), omit step 4.
4. Perform SYSTEMS POWER DOWN (para 32).
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
ROCKET CONTROL
PANEL NOGO
PILOTS
COMPARTMENT
Troubleshoot wiring to isolate
fault TM 9-1090-208-23-2. If
troubleshooting does not
remove NOGO, replace
ROCKET panel
(TM 9-1090-208-23-1). If
replacement does not
remove NOGO, refer to
TM 9-1090-208-23-2.
(All) STATION
DIRECTOR NOGO
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2).
STATION DIRECTOR
NOGO LT OUTBD/LT
INBD
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2).
STATION DIRECTOR
NOGO RT INBD/RT
OUTBD
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2).