TM 11520238T1
488
Change 4
412 STAB INTERACTIVE FD/LS CHECK
412
(ACY) (cont)
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
TOP STAB
ACTUATOR NOGO
TAIL SECTION
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7). If
troubleshooting does not
remove NOGO, replace top
stabilator actuator
(TM 1-1520-238-23). If
replacement does not
remove NOGO, refer to
TM 1-1520-238-T-7.
BOTTOM STAB
ACTUATOR NOGO
TAIL SECTION
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7). If
troubleshooting does not
remove NOGO, replace
bottom stabilator actuator
(TM 1-1520-238-23). If
replacement does not
remove NOGO, refer to
TM 1-1520-238-T-7.
RATE GYRO 1 NOGO
LH AFT CATWALK
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7). If
troubleshooting does not
remove NOGO, replace rate
gyro 1 (TM 1-1520-238-23). If
replacement does not
remove NOGO, refer to
(TM 1-1520-238-T-7).
RATE GYRO 2 NOGO
RH AFT CATWALK
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7). If
troubleshooting does not
remove NOGO, replace rate
gyro 2 (TM 1-1520-238-23). If
replacement does not
remove NOGO, refer to
TM 1-1520-238-T-7.