434 DNS INTERACTIVE FD/LS CHECK
434
(ADD) (cont)
TASK
RESULT
c. On CDU, press and
release 0 and 8
keys.
If any MUX NOGO appears
on HOD, refer to
TM 9-1230-476-20-2 for
troubleshooting the MUX
system.
When MUX
COMMUNICATION GO
appears on the HOD, go to
next step.
e. On CDU, press and
release 3 and 4
keys.
If one or more FD/LS
NOGO displays listed
appear on the HOD, perform
the following in sequence.
(1) Perform SYSTEMS
POWER DOWN
(para 32) and APU
shutdown (para 33).
(2) Perform CORRECTIVE
ACTION indicated for first
NOGO displayed on
HOD.
(3) Perform SYSTEMS
POWERUP
(para 31).
(4) Repeat FD/LS check
beginning with step 2. If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 11-1520-238-23-2.
3. Perform SYSTEMS POWER DOWN (para 32) if
power no longer required.
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
SIGNAL DATA
CONVCOMP
NOGO LH AFT
CATWALK
Replace SDCC
TM 11-1520-238-23-1.
RCVRXMTR ASSY
NOGO BELLY
Troubleshoot wiring to isolate
fault TM 11-1520-238-23-2.