TM 11520238T2
2119
Table 21.
Master Failure Symptom Index (cont)
Failure Symptom
MOC
Reference
MSL L OUTBD LCHR DC CIRCUIT BREAKER
(CB25) DOES NOT STAY CLOSED (PILOT
ELEC PWR PANEL: BATT/EXT PWR SWITCH
SET TO EXT PWR)
TM 11520238T6
CIRCUIT
PROTECTION
SYSTEM (DC
GROUND CIRCUIT
BREAKERS CPG
STATION)
MSL R INBD LCHR AC CIRCUIT BREAKER
(CB21) DOES NOT STAY CLOSED (PILOT
ELEC PWR PANEL: BATT/EXT PWR SWITCH
SET TO EXT PWR)
TM 11520238T6
CIRCUIT
PROTECTION
SYSTEM (AC
ESSENTIAL BUS 1
CPG STATION)
MSL R INBD LCHR DC CIRCUIT BREAKER
(CB22) DOES NOT STAY CLOSED (PILOT
ELEC PWR PANEL: BATT/EXT PWR SWITCH
SET TO EXT PWR)
TM 11520238T6
CIRCUIT
PROTECTION
SYSTEM (DC
GROUND CIRCUIT
BREAKERS CPG
STATION)
MSL R OUTBD LCHR AC CIRCUIT BREAKER
(CB18) DOES NOT STAY CLOSED (PILOT
ELEC PWR PANEL: BATT/EXT PWR SWITCH
SET TO EXT PWR)
TM 11520238T6
CIRCUIT
PROTECTION
SYSTEM (AC
ESSENTIAL BUS 1
CPG STATION)
MSL R OUTBD LCHR DC CIRCUIT BREAKER
(CB19) DOES NOT STAY CLOSED (PILOT
ELEC PWR PANEL: BATT/EXT PWR SWITCH
SET TO EXT PWR)
TM 11520238T6
CIRCUIT
PROTECTION
SYSTEM (DC
GROUND CIRCUIT
BREAKERS CPG
STATION)
MSL SEL? DOES NOT APPEAR ON HOD (CPG
CYCLIC STICK: R/G/M/C SWITCH
MOMENTARILY SET TO M)
TM 9142747520
HME SYSTEM
MSL SEL? DOES NOT APPEAR ON HOD (ORT
LH GRIP: RKT/GUN/MSL SWITCH SET TO
MSL)
TM 9142747520
HME SYSTEM
MU APPEARS ON HOD (PILOT FCP: MASTER
SWITCH SET TO ARM AND CPG FCP: CPG
SWITCH SET TO ARM)
TM 9142747520
HME SYSTEM