TM 11520238T2
Change 4
2173
Table 21.
Master Failure Symptom Index (cont)
Failure Symptom
MOC
Reference
STAB POS INDICATORS DO NOT INDICATE 35
2 ND (PITOT TESTER: AIRSPEED
REDUCED TO ZERO (0) KNOTS) (CPG
COLLECTIVE STICK: ND/NU SWITCH
PULSED TO ND POSITION UNTIL
STABILATOR REACHES DOWN LIMIT)
TM 11520238T7
STABILATOR
STAB POS INDICATORS DO NOT INITIALLY
INDICATE 25 2 ND THEN DECREASES TO
20 2 (PITOT TESTER: AIRSPEED SET TO
60 2 KNOTS)
TM 11520238T7
STABILATOR
STAB POS INDICATORS SHOW MOVEMENT
(PITOT TESTER: AIRSPEED SET TO 85 2
KNOTS) (PILOT COLLECTIVE STICK: ND/NU
SWITCH PULSED TO ND FOR TWO
SECONDS)
TM 11520238T7
STABILATOR
STAB POS NOT AT 2 2 NU FOR 165 KNOTS
AND COLLECTIVE CENTERED
TM 11520238T7
STABILATOR
STAB POS NOT AT 19 2 NU FOR 70 KNOTS
AND COLLECTIVE CENTERED
TM 11520238T7
STABILATOR
STABILATOR DOES NOT MOVE TO WITHIN 2
OF 9 NU (PILOT COLLECTIVE STICK: ND/NU
SWITCH PULSED TO NU UNTIL STAB POS
INDICATOR INDICATES FULL UP POSITION)
TM 11520238T7
STABILATOR
STABILATOR DOES NOT MOVE EITHER UP OR
DOWN OR STAB MAN DC CIRCUIT BREAKER
DOES NOT STAY CLOSED
TM 11520238T7
STABILATOR
STATION DIRECTOR NOGO LT INBD AND LT
OUTBD APPEARS ON HOD
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM
STATION DIRECTOR NOGO LT INBD APPEARS
ON HOD
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM
STATION DIRECTOR NOGO LT OUTBD
APPEARS ON HOD
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM
STATION DIRECTOR NOGO RT INBD AND RT
OUTBD APPEARS ON HOD
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM
STATION DIRECTOR NOGO RT INBD
APPEARS ON HOD
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM
STATION DIRECTOR NOGO RT OUTBD
APPEARS ON HOD
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM