TM 11520238T3
Change 4
315
362 SIGNAL NAME:
AD REF VOLTAGE FAIL (ACY) ADA REF STAT (ACZ)
MEMORY LOCATION: 002103
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of one of analogtodigital converters during a DASEC internal
wraparound test.
REMARKS: From DASEC to FCC.
PASS:
If second digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 363.
FAIL: Location of fault: replace DASEC (TM 1152023823).
363 SIGNAL NAME:
HARS INPUT NOT CHANGING (ACY) HARS DATA STAT (ACZ)
MEMORY LOCATION: 002103
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of HARS input data.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 364.
FAIL: Location of fault: refer to Chapter 6, paragraph 614.
364 SIGNAL NAME:
COLL WRAPAROUND DISCRETE (ACY) COLL WRAP STAT (ACZ)
MEMORY LOCATION: 002103
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of DASEC collective (vertical) servoactuator drive digital
interface signal.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 0 or 1, go to paragraph 365.
FAIL: Location of fault: replace DASEC (TM 1152023823).
365 SIGNAL NAME:
YAW WRAPAROUND DISCRETE (ACY) YAW WRAP STAT (ACZ)
MEMORY LOCATION: 002103
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of DASEC tail rotor actuator drive digital interface signal.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 0, go to paragraph 366.
FAIL: Location of fault: replace DASEC (TM 1152023823).
366 SIGNAL NAME:
ROLL WRAPAROUND DISC INVALID (ACY) ROLL WRAP STAT (ACZ)
MEMORY LOCATION: 002104
MEMORY DATA BIT(S):
4
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of DASEC lateral (roll) servoactuator drive digital interface
signal.
REMARKS: From DASEC to FCC.
PASS:
If sixth digit displayed on HOD is 0, go to paragraph 367.
FAIL: Location of fault: replace DASEC (TM 1152023823).