TM 11520238T3
Change 4
321
390 SIGNAL NAME:
HARS FAIL (ACY) HARS TEST STAT (ACZ)
MEMORY LOCATION: 002106
MEMORY DATA BIT(S):
6
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates capability of HARS to supply data to DASEC.
REMARKS: From DASEC to FCC.
PASS:
If fifth digit displayed on HOD is 0 or 1, go to paragraph 391.
FAIL: Location of fault: refer to Chapter 6, paragraph 69.
391 SIGNAL NAME:
AIR DATA FAIL (ACY) ADS TEST STAT (ACZ)
MEMORY LOCATION: 002106
MEMORY DATA BIT(S):
7
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates capability of air data system (ADS) to function properly and to supply
data to DASEC.
REMARKS: From DASEC to FCC.
PASS:
If fifth digit displayed on HOD is 0, go to paragraph 392.
FAIL: Location of fault: refer to Chapter 2, paragraph 23.
392 SIGNAL NAME:
LONG ACT FAIL (ACY) LONG ACTR STAT (ACZ)
MEMORY LOCATION: 002106
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates capability of longitudinal (pitch) servoactuator to respond correctly to
DASEC commands.
REMARKS: From DASEC to FCC.
PASS:
If fourth digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 393.
FAIL: Location of fault: longitudinal (pitch) servoactuator, wiring from longitudinal (pitch) servoactuator
to DASEC. Troubleshoot wiring to isolate fault (TM 11520238T7).
393 SIGNAL NAME:
LAT ACT FAIL (ACY) LAT ACTR STAT (ACZ)
MEMORY LOCATION: 002106
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates capability of lateral (roll) servoactuator to respond correctly to DASEC
commands.
REMARKS: From DASEC to FCC.
PASS:
If third digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 394.
FAIL: Location of fault: lateral (roll) servoactuator, wiring from lateral (roll) servoactuator to DASEC.
Troubleshoot wiring to isolate fault (TM 11520238T7).
394 SIGNAL NAME:
DIR ACT FAIL (ACY) DIR ACTR STAT (ACZ)
MEMORY DATA BIT(S):
002106
MEMORY LOCATION: 12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates capability of tail rotor actuator to respond correctly to DASEC
commands.
REMARKS: From DASEC to FCC.
PASS:
If third digit displayed on HOD is 0 or 1, go to paragraph 395.
FAIL: Location of fault: tail rotor actuator, wiring from tail rotor actuator to DASEC. Troubleshoot
wiring to isolate fault (TM 11520238T7).