TM 11520238T3
73
73 SIGNAL NAME:
IHADSS SYSTEM STATUS
MEMORY LOCATION: 001530
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors IHADSS system.
REMARKS: From sight electronics unit (SEU) through righthand (RH) forward avionics bay (FAB)
MRTU Type I to FCC.
PASS:
If fourth digit on HOD is 0, 1, 4, or 5, go to paragraph 74.
FAIL: Location of fault: SEU, wiring from SEU to RH FAB MRTU Type I, RH FAB MRTU Type I.
Troubleshoot wiring to isolate fault (TM 9127022123).
74 SIGNAL NAME:
IHADSS TIME DELAY 1
MEMORY LOCATION: 001562
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
HOD displays all zeros.
SIGNAL FUNCTION:
Monitors IHADSS response time delay.
REMARKS: From SEU through RH FAB MRTU Type I to FCC.
PASS:
If condition is met, go to paragraph 75.
FAIL: Location of fault: SEU, wiring from SEU to RH FAB MRTU Type I, RH FAB MRTU Type I.
Troubleshoot wiring to isolate fault (TM 9127022123).
75 SIGNAL NAME:
IHADSS TIME DELAY 2
MEMORY LOCATION: 001563
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
HOD displays all zeros.
SIGNAL FUNCTION:
Monitors IHADSS response time delay.
REMARKS: From SEU through RH FAB MRTU Type I to FCC.
PASS:
If condition is met, go to paragraph 76.
FAIL: Location of fault: SEU, wiring from SEU to RH FAB MRTU Type I, RH FAB MRTU Type I.
Troubleshoot wiring to isolate fault (TM 9127022123).
76 SIGNAL NAME:
IHADSS TIME DELAY 3
MEMORY LOCATION: 001564
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
HOD displays all zeros.
SIGNAL FUNCTION:
Monitors IHADSS response time delay.
REMARKS: From SEU through RH FAB MRTU Type I to FCC.
PASS:
If condition is met, go to paragraph 77.
FAIL: Location of fault: SEU, wiring from SEU to RH FAB MRTU Type I, RH FAB MRTU Type I.
Troubleshoot wiring to isolate fault (TM 9127022123).
77 SIGNAL NAME:
IHADSS TIME DELAY 4
MEMORY LOCATION: 001565
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
HOD displays all zeros.
SIGNAL FUNCTION:
Monitors IHADSS response time delay.
REMARKS: From SEU through RH FAB MRTU Type I to FCC.
PASS:
If condition is met, go to paragraph 78.
FAIL: Location of fault: SEU, wiring from SEU to RH FAB MRTU Type I, RH FAB MRTU Type I.
Troubleshoot wiring to isolate fault (TM 9127022123).