TM 11520238T3
Change 4
841
8133 SIGNAL NAME:
P1M1 MSL COAX B CONNECT
MEMORY LOCATION: 001714
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax B to indicated missile.
REMARKS: From launcher through left outboard MRTU Type II to FCC.
PASS:
If first digit on HOD is 4, 5, 6, or 7, go to paragraph 8134.
FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboard
MRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8134 SIGNAL NAME:
P1M1 MSL COAX A CONNECT
MEMORY LOCATION: 001300
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax A to indicated missile.
REMARKS: From RHE to ECSP.
PASS:
If first digit on HOD is 2, 3, 6, or 7, go to paragraph 8135.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8135 SIGNAL NAME:
P1M1 MSL COAX A CONNECT
MEMORY LOCATION: 001714
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax A to indicated missile.
REMARKS: From launcher through left outboard MRTU Type II to FCC.
PASS:
If first digit on HOD is 2, 3, 6, or 7, replace RHE (TM 9142747520).
FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboard
MRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8136 SIGNAL NAME:
P1M1 MSL SKR LAUNCH PREPARE COMMAND (ACY)
P1M1 SKR LNCH CMD (ACZ)
MEMORY LOCATION: 001300
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Prepares missile for free flight operation.
REMARKS: From RHE to ECSP.
PASS:
If first digit on HOD is 0, 2, 4, or 6, go to paragraph 8137.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8137 SIGNAL NAME:
P1M1 MSL SKR LAUNCH PREPARE COMMAND (ACY)
P1M1 SKR LNCH CMD (ACZ)
MEMORY LOCATION: 001714
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Prepares missile for free flight operation.
REMARKS: From launcher through left outboard MRTU Type II to FCC.
PASS:
If first digit on HOD is 0, 2, 4, or 6, go to paragraph 81126.
FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboard
MRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).